Skip to Main Content
IBM Z Hardware and Operating Systems Ideas Portal


This is the public portal for all IBM Z Hardware and Operating System related offerings. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

Clear

Ideas

Showing 43 of 3838

XCF_CDS_SPOF Healthcheck

Provide customization to exclude mirrored Logger CDS from the SPOF healthcheck, because mirrored CDS are not a SPOF.
4 months ago in z/OS / BCP_XCF/XES 2 Not under consideration

Possibility to choose the systems to make the XCF Rebuild Copy Process

We think it is important to have the option to choose the systems that will do the system managed rebuild of CF structures by defining a preference list, for example.We had a case where we verified that the system that was doing the copy was a GDP...
almost 7 years ago in z/OS / BCP_XCF/XES 0 Future consideration

Set a Preference List for Monitoring System of a Coupling Facility

We think it is important to set which system will be responsable for monitoring full threshold of a specificCoupling Facility. In environments with GDPS, Ksys should have no product running unless GDPS own, on the recommendationthe GDPS, to not ha...
about 9 years ago in z/OS / BCP_XCF/XES 0 Future consideration

XCF_CF_STR_NONVOLATILE should have customizable STR-exclusion list

The health check XCF_CF_STR_NONVOLATILE should be customizable in a way that you can specify a list of structure names that should be excluded from the check.
almost 9 years ago in z/OS / BCP_XCF/XES 0 Future consideration

Structure-level control of CF CPU utilization

As discussed in PMR, we had a high consumption problem of a WMQ structure in a CF impacting other users of the CF. Consumption CF reached 90%, and the consumption of structure in question has reached 80% of CF.We need a way to control the use of t...
about 9 years ago in z/OS / BCP_XCF/XES 2 Not under consideration

SETXCF REALLOCATE with CF storage release delay

SETXCF REALLOCATE processing should be enhanced to handle temporary storage delay when CF performing structure space cleanup.
almost 6 years ago in z/OS / BCP_XCF/XES 0 Future consideration

IXCMIAPU Should Be Updated to Return The Default Value of Each Structure Attriubte To The CFRM Policy Editor

The CFRM Policy Editor is intended to make it easier and more efficient to manage the CFRM policy. There are many Structure attributes that are assigned default values if the user does not assign a specific value. While those default values are sh...
almost 4 years ago in z/OS / BCP_XCF/XES 2 Future consideration

REALLOCATE executed on System with LOSSCONN to CF and failed

After a loss of connectivity for 2 out of 14 z/OS images to a CF, the client put the problem CF in MAINTMODE and did a SETXCF REALLOCATE to clear the structures to do hardware recovery. The REALLOCATE process shifted to one of the 2 z/OS images th...
almost 6 years ago in z/OS / BCP_XCF/XES 0 Future consideration

parameter to suppress IXL014I, IXL015I, and IXL016I messages when accessing coupling facility structures.

Having a parameter on the IXL* calls would be nice to be able to suppress the IXL* messages that come out.
8 months ago in z/OS / BCP_XCF/XES 1 Not under consideration

Ansible automation for OpenShift deployment on Linuxone with z/VM hypervisor

Ansible Playbooks to automate a User-Provisioned Infrastructure (UPI) deployment of Red Hat OpenShift Container Platform (RHOCP) with z/VM hypervisor. This process, when done manually, is extremely tedious, time-consuming, and requires high levels...
over 2 years ago in Linux on IBM Z and LinuxONE 1 Not under consideration