Skip to Main Content
IBM Z Hardware and Operating Systems Ideas Portal


This is the public portal for all IBM Z Hardware and Operating System related offerings. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

BCP_XCF/XES

Showing 36 of 3553

Structure-level control of CF CPU utilization

As discussed in PMR, we had a high consumption problem of a WMQ structure in a CF impacting other users of the CF. Consumption CF reached 90%, and the consumption of structure in question has reached 80% of CF.We need a way to control the use of t...
about 8 years ago in z/OS / BCP_XCF/XES 1 Future consideration

REALLOCATE executed on System with LOSSCONN to CF and failed

After a loss of connectivity for 2 out of 14 z/OS images to a CF, the client put the problem CF in MAINTMODE and did a SETXCF REALLOCATE to clear the structures to do hardware recovery. The REALLOCATE process shifted to one of the 2 z/OS images th...
almost 5 years ago in z/OS / BCP_XCF/XES 0 Future consideration

XCF_CF_STR_NONVOLATILE should have customizable STR-exclusion list

The health check XCF_CF_STR_NONVOLATILE should be customizable in a way that you can specify a list of structure names that should be excluded from the check.
almost 8 years ago in z/OS / BCP_XCF/XES 0 Future consideration

Improved CF Task and z/OS Subchannel Queue Management

Today, queueing based on subchannel availability is all-or-nothing, for all structures, and any one CF structure can consume 100% of the available subchannels during a spike, causing queueing and delays for all CF structures•APAR OA41203 does not ...
about 7 years ago in z/OS / BCP_XCF/XES 0 Future consideration

Parm to remove report lines from IXCMIAPU

Please add a PARM to IXCMIAPU so that it does not issue line breaks, page counts and report headers ADMINISTRATIVE DATA UTILITY: REPORT DATA TYPE = CFRM 06/12/2019 17:30:16 PAGE 4 ___________________________________________________________________...
over 5 years ago in z/OS / BCP_XCF/XES 0 Future consideration

MONITORING CF LINKS

IBM defined a specific msg-ID IXL158I to identify CF Link with status NOT OPERATIONAL but we don't have msg-ID when the link is ONLINE-DEGRADED. Instead, link DEGRADED is provided as a result of the command /D CF,CFNM=CFXX but isn't the more effic...
about 8 years ago in z/OS / BCP_XCF/XES 1 Future consideration

XCF CDS Maxsystem Definitation

Reducing the Max system count for the XCF CDS's you can add the new CDS to the system with out a full sysplex IPL.
over 5 years ago in z/OS / BCP_XCF/XES 0 Future consideration

REALLOCATE TEST should provide more screening for potential structure duplexing issues.

REALLOCATE TEST needs to provide additional screening for potential structure duplexing issues. For example, if a REALLOCATE is performed while a structure is in simplex mode with DUPlEX(ENABLED) . and only failed-persistent structures, the REALLO...
over 3 years ago in z/OS / BCP_XCF/XES 0 Future consideration

Sysplex couple dataset has insufficient room for growth

Health check XCF_SYSPLEX_CDS_CAPACITY alerts with message IXCH0602E indicating one of the Sysplex couple dataset resources has hit the maximum threshold. Message IXCH0911I informs which kind of resource (XCF GROUPS, XCF GROUP MEMEBERS or SYSTEMS) ...
almost 7 years ago in z/OS / BCP_XCF/XES 1 Future consideration

PAVA0903-593 ARM policy TERMTYPE(SYSTERM)needed (Gerrit Bakker)

SUBMITTER SECTIONSubmitted by: CN=Arlene Berchtold/OU=Poughkeepsie/O=IBMSubmitters Company: Workgroup Generated PUBLICRequirement Number and Title: PAVA0903-593 ARM policy TERMTYPE(SYSTERM)needed (Gerrit Bakker)Homework Assigned: NoRequirement Cat...