Skip to Main Content
IBM Z Hardware and Operating Systems Ideas Portal


This is the public portal for all IBM Z Hardware and Operating System related offerings. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

z/VM

Showing 378 of 3553

z/VM RACF SMF Report Writer Enhancements

Request to enhance RACFVM Report Writer to be compatible with RACFVM z/VM 7.2 and later releases.
about 3 years ago in z/VM 0 Future consideration

z/VM TCPIP utilities (PING FTP TELNET TRACERTE) use the first address returned from a DNS server. This may be an IPV6 address - if the originating system is only IPV4 the result is "EDC8118I Network is unreachable". This can be bypassed by using the ADDRTYPE arg but we would prefer smarter DNS lookup. z/OS and zLinux handle this without using ADDRTYPE.

See "Your idea".
about 2 years ago in z/VM 0 Future consideration

Install correct USER DIRECT when selecting non-SSI install

When installing zVM 7.3 we chose the option non-SSI install, but the USER DIRECT that was included is in the format of SSI/SSI Ready. This means that when companies grow their system beyond the very limited 8 nodes of SSI they will have to manuall...
about 2 years ago in z/VM 0 Future consideration

Make z/VM TCPIP FTP server RFC 3659 compliant

We've recently implemented z/VM 7.1 after being away from z/VM for many, many years. During the setup and installation we tailored TCPIP and specifically the FTP server but discovered that it is not compatible with GUI FTP clients like the FileZil...
over 5 years ago in z/VM 2 Future consideration

CMSSTOR macro support relative addressing instructions

Change the inline re-entrant expansion form of the CMSSTOR macro to use relative addressing, thereby eliminating the need for a base register in the CSECT. The sequence of CNOP 0,4 / LA R1,*+8 (Plist address) / BC 15,Around_Plist / (inline_plist) ...
over 6 years ago in z/VM 0 Future consideration

Ansible support for z/VM unique functionality

NatWest would like to be able to use Ansible to automate/orchestrate its z/VM unique resources such as z/VM customized z/OS guests (both virtual hardware and software), virtual coupling facility, z/VM customized z/Linux guests (both virtual hardwa...
over 4 years ago in z/VM 0 Future consideration

Report on the database minidisks used by the RACF server via the RACONFIG interface (Diagnose x'0A0' subfunction 0050)

The RACONFIG interface returns the DataSet Descriptor Table (DSDT) when diagnose 0A0-0050 is called with the TYPDSDT bit set.This returns the pairs of primary/backup data set names / file names, that by default map to RACFVM 200/300 210/310 211/31...
about 1 year ago in z/VM 0 Future consideration

Allow SSI connection between z/VM systems using Hipersockets (direct and bridged)

Requiring physical CTC connections for an SSI cluster within a single physical CEC incurs some cost for additional hardware (e.g. preferably 2 FICON cards for SPOF avoidance). Modifying ISFC communication to optionally use Hipersockets would allow...
about 1 year ago in z/VM 1 Not under consideration

ICHPWX01 and IRRPWREX sample files for RACF on zVM

We need sample ICHPWX01 and IRRPWREX sample files so that we can code the REXX exec to comply with our specific password security requirements.
almost 6 years ago in z/VM 4 Planned for future release

INSTPIPE FTPGET should support secure FTP

Installing 7.1 second level with media on an FTP server. FTP traffic at our site must be encrypted. INSTPIPE FTPGET should support encrypted FTP for server installs.
almost 6 years ago in z/VM 0 Future consideration