Skip to Main Content
IBM Z Hardware and Operating Systems Ideas Portal


This is the public portal for all IBM Z Hardware and Operating System related offerings. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

All ideas

Showing 3549

Would Like to see CPM More Agressive for Increasing Group Capping

We would like to see Capacity Provisioning Manager be more aggressive for increasing the group cap by giving the user more options and more granularity. In our case it took an hour before CPM increased the group cap.
over 8 years ago in z/OS / BCP_Capacity Provisioning 2 Future consideration

Please Add Exit for FTP JCL Errors

One of our customers has an JCL job with an FTP step. They are using SITE parameters in that step. When there is an error on the SITE parameter, the user wants to the job to exit with a RC higher than 0. They would prefer RC16. I am not able to he...
over 4 years ago in z/OS / Communications Server 0 Not under consideration

Need to break up roles for IPSEC command

We need to get the –f default and the –f reload IPSEC commands seperated from our the other standared commands on the system. This will allow us to assign the proper rolls to them for elevated access. This would also be true for Defense Management...
over 4 years ago in z/OS / Communications Server 0 Future consideration

Change to the wording of $HASP865 CONFIRM MEMBER(004) NAME=xxxx IS TO BE ADDED

The wording of this Jes2 WTOR does not provide enough information for our operators to make a decision $HASP865 CONFIRM MEMBER(004) NAME=HOD9 IS TO BE ADDED It would be more constructive for the WTOR to read as follows :- $HASP865 CONFIRM MEMBER(0...
over 4 years ago in z/OS / JES2 0 Future consideration

LE modification for fork thread behaviour

There are multiple instances in the the core python implementation and in pypi packages where a thread calls fork and the child process tries to create a thread using pthread_create but results in an error. This error is due to the LE design ...
over 4 years ago in z/OS / LE 0 Future consideration

Netcat command unavailable to use with ProxyCommand (trying to SFTP thru Proxy Server)

I tried to sftp thru ProxyServer using option ProxyCommand. Using directiver from openssh.org it is advised to use netcat command, which does not exist in Open Ported Tools.
over 8 years ago in z/OS / OpenSSH 2 Future consideration

FICON Status reporting

JPMC would like another option other than CONFIGxx on z/OS to report the status of channels on their z13's using Automation. A WEB API to submit a query to all channels for the operating status, then they would take the information returned and co...
over 8 years ago in IBM Z and LinuxONE Systems Hardware / HMC/Support Element (SE) 3 Planned for future release

RACUT200 should verify if RACF is not already running if executed in RACFVM user.

The RACUT200 utility (but also RACSTART) should verify that RACF is not already running when executed before continue its execution.
over 8 years ago in z/VM 2 Planned for future release

NTP server required because SNTP is not precise enough

Implement a NTP server that is more accurate than SNTP server.
over 4 years ago in z/OS / Communications Server 2 Not under consideration

Cipher Text Translate to suport ASYM<-->SYMMETRIC translations

3rd party clients are using ASYM PKCS11 encrypt/decrypt to send for example CC numbers to us. Vice Versa as well. Local DB2 database stores the CC numbers using a symmetric key.Would like a enhancement to CIPHER text translate or new function to p...
over 8 years ago in IBM Z and LinuxONE Systems Hardware / Crypto HW 10 Not under consideration