Skip to Main Content
IBM Z Hardware and Operating Systems Ideas Portal


This is the public portal for all IBM Z Hardware and Operating System related offerings. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

All ideas

Showing 3569

PDSE member count limit

Until z/OS V2R3 PDSE allows for member creation until it reaches the count of 522,239 members. After that, we get message IEC306I : IEC036I A WRITE would have had to create another member in a PDSE which already contained the maximum allowable num...
over 5 years ago in z/OS / DFSMS Access Methods Non-Vsam 1 Future consideration

Information about device status for channel path on message IEE174I

The form 17 of message IEE174I in response to the command DISPLAY M=CHP(chpid) shows the channel path status to the device despite the title shown on display being “DEVICE STATUS FOR CHANNEL PATH chpid” The information showing z/OS device status f...
over 5 years ago in z/OS / BCP_IOS 1 Future consideration

HMC/SE LDAP Group Replication/LDAP Server Connection Validation for HMC/SE Disabled ACSADMIN user

The LDAP Groups configuration needs to be replicated automatically from the HMC to the SE. This will allow the HMC user being used at the SE to utilize LDAP Groups without manually adding that LDAP Group config at the SE. For a single disabled ACS...
8 months ago in IBM Z and LinuxONE Systems Hardware / HMC/Support Element (SE) 0 Planned for future release

zOSMF Configuation Assistant AT-TLS reusable rules

In working with the Configuration Assistant we have found that with the IPSEC Reusable Rules we can create a rule that is easy to move between stacks. Having this capability for AT-TLS rule would also be helpful.
about 9 years ago in z/OS / Communications Server 3 Not under consideration

After zEDC Outage IFASMFDL ends with RC4 but dumps no data

If there is any Problem with dumping from a logstream, IFASMFDL should not end with RC4 but with RC8 or RC16 as soon as the data dumped from the stream is reduced due to the error.
over 7 years ago in z/OS / BCP_SMF 0 Future consideration

Add SMF119AP_TTStatus to SMF119 Subtype 1 Connection Init

Add the field SMF119AP_TTStatus to the SMF 119 Subtype 1 Connection Initialization record. This field was already added to the subtype 2 - termination record, but should also exist in the init record. This information is known to the system at con...
about 2 years ago in z/OS / Communications Server 0 Future consideration

Some RACF commands issue misleading error messages

When issuing a RACF command such as ADDUSER or ADDGROUP RACF issues misleading messages when the user or group exists. Additional misleading messages can also be issued about OMVS.For instance, when DFSGRP exists:ADDGROUP DFSGRP SUPGROUP(SYS1) OMV...
almost 7 years ago in z/OS / RACF 5 Not under consideration

Provide the ability to create only the volume label on a DASD volume using ICKDSF

We have seen occasions where something is overwriting just the volume label on cylinder 0, track 0 but the remaining data on the volume remains in tact. This causes the volume to be inaccessible along with all of the data on it. There should be a ...
over 1 year ago in z/OS / DFSMS ICKDSF 3 Functionality already exists

During zOSMF upgrade of zOS add the ability to connect Old Usercat to New Mastercat

For as long as Serverpac has been available (and maybe even before) when doing a zOS upgrade I create a New Master catalog and connect an old User Catalog to it which contains datasets that start with SYSINST in it. SYSINST is used for Serverpac d...
about 2 years ago in z/OS / SMP/E 1 Future consideration

Ansible automation for OpenShift deployment on Linuxone with z/VM hypervisor

Ansible Playbooks to automate a User-Provisioned Infrastructure (UPI) deployment of Red Hat OpenShift Container Platform (RHOCP) with z/VM hypervisor. This process, when done manually, is extremely tedious, time-consuming, and requires high levels...
over 1 year ago in Linux on IBM Z and LinuxONE 1 Not under consideration