Skip to Main Content
IBM Z Hardware and Operating Systems Ideas Portal


This is the public portal for all IBM Z Hardware and Operating System related offerings. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

All ideas

Showing 3554

LE modification for fork thread behaviour

There are multiple instances in the the core python implementation and in pypi packages where a thread calls fork and the child process tries to create a thread using pthread_create but results in an error. This error is due to the LE design ...
over 4 years ago in z/OS / LE 0 Future consideration

FICON Status reporting

JPMC would like another option other than CONFIGxx on z/OS to report the status of channels on their z13's using Automation. A WEB API to submit a query to all channels for the operating status, then they would take the information returned and co...
over 8 years ago in IBM Z and LinuxONE Systems Hardware / HMC/Support Element (SE) 3 Planned for future release

RACUT200 should verify if RACF is not already running if executed in RACFVM user.

The RACUT200 utility (but also RACSTART) should verify that RACF is not already running when executed before continue its execution.
over 8 years ago in z/VM 2 Planned for future release

Cipher Text Translate to suport ASYM<-->SYMMETRIC translations

3rd party clients are using ASYM PKCS11 encrypt/decrypt to send for example CC numbers to us. Vice Versa as well. Local DB2 database stores the CC numbers using a symmetric key.Would like a enhancement to CIPHER text translate or new function to p...
over 8 years ago in IBM Z and LinuxONE Systems Hardware / Crypto HW 10 Not under consideration

NTP server required because SNTP is not precise enough

Implement a NTP server that is more accurate than SNTP server.
over 4 years ago in z/OS / Communications Server 2 Not under consideration

HCD unattended Export to allow replace an old IODF in different disk.

HCD unattended export with replace leaves IODF in old disk, not the one specified in the panel. Wait state obtained in IPL because IODF file was not in the intended disk, the one in the LOADPARM. IODF file was created by HCD export from other sysp...
over 8 years ago in z/OS / HCD 3 Not under consideration

Improvement on FFDC for z/OS & VTS mount state discrepencies

We have had many instances over the years of mismatches between the VTS device mount state in the VTS and z/OS. The latest of these was being pursued through PMR 15331,122,000. In almost all of these instances we get some notification through a z/...
almost 9 years ago in z/OS / DFSMS Tape Storage SW Support 2 Future consideration

Support for multiple IP-stack per LPAR for use with CP&M resource pools

We have multiple IP-stacks per LPAR.There currently is a limitation to use more than one per LPAR for CP&M Resource pools. This limits us from using CP&M Resource pools cloud provisioning of IP-adresses, which is a very important part of p...
over 4 years ago in z/OS / Communications Server 2 Not under consideration

Need for ISPF alternate translate table for Cyrillic terminal (3278CY now)

Current translate table for ISPF Terminal Type 3278CY defines as valid some symbols which are really invalid for PC3270 session with Host Code Page 1025 Russia, we found the following symbols:x'42', x'54', x'62', x'72', x'75'We need the alternate ...
almost 9 years ago in z/OS / ISPF 3 Not under consideration

Provide capability to format OSAENTA (concurrently taken from multiple OSAs) in timestamp order

When using IPCS to format OSAENTA traces, have the resulting output be presented in timestamp order even when the input contains traces from different OSAs.
almost 9 years ago in z/OS / Communications Server 0 Not under consideration