Skip to Main Content
IBM Z Hardware and Operating Systems Ideas Portal


This is the public portal for all IBM Z Hardware and Operating System related offerings. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

Status Future consideration
Workspace z/OS
Categories DFSMS HSM
Created by Guest
Created on Aug 12, 2015

Need BYPASSACS option for Migrate Volume(xxxxxx) Move

When using the DFSMShsm new function to do MIGRATE VOLUME(xxxxxx) MOVE, we need a possibility to bypass ACS routines so that manually or JCL-assigned SMS-classes are retained for datasets on selected volumes. The parameter BYPASSACS could be added for this command to give the same possibility as when using DFSMSdss for moving data from given volumes.

Idea priority High
  • Guest
    Reply
    |
    May 20, 2022

    In the ACS routines you can have a check when &ACSENVIR=RECALL that the class passed is a match to a FILTLIST of valid ones, and set the class to that value.

  • Guest
    Reply
    |
    Aug 14, 2015

    I'll add this to our 'short list' of small enhancements.

  • Guest
    Reply
    |
    Aug 13, 2015

    Creating a new RFE based on Community RFE #75336 in product z/OS.