Skip to Main Content
IBM Z Hardware and Operating Systems Ideas Portal


This is the public portal for all IBM Z Hardware and Operating System related offerings. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

Status Not under consideration
Created by Guest
Created on Mar 14, 2019

Improvemet for recovery from MCL out of sync status

The failure of SE console HDD were occurred during MCL apply.
Then it was MCL out of sync status.
If the difference between MCL of SE Console and MCL of CPC is 1 Level, POR (Power on Reset) is not required for recovery.
However, if it is 2 levels or more, POR is required for recovery.
Now in some case MCL include 2 levels or more differentiations.
Customer uses IBM Z as a mission-critical system and required 24 x 365 continuous operations.
So customer don't accept POR for those reasons that SE HDD failure occurs and MCL differentiations is 2 levels or more.
Therefore customer desires improvement for microcode to eliminate the possibility of needing POR due to SE Console HDD failure.
Alternatively, an improvement such that MCL difference is always released at 1 Level is also acceptable.

Idea priority Urgent
  • Guest
    Reply
    |
    Nov 13, 2019

    Based on review of the history and data between IBM and Nippon Steel it was decided that no action would be done for this RFE.

  • Guest
    Reply
    |
    Apr 11, 2019


    SE console HDD failure occurred when Customer Engineer applying MCL. (PMR 10428,6V5,760)
    SE HDD failure cause MCL Out of Sync state.
    Depending on the situation, recovery for MCL Out of Sync need POR (Power On Reset).


    One of request from customer is that HDD mirroring(RAID) configuration will be selectable.
    Even if z114 is impossible, it is good if it can be realized by latest z(z14ZR1).
    Because IBM is selling z14ZR1 for this customer for upgrade from this z114.

  • Guest
    Reply
    |
    Apr 9, 2019

    Brian Valentine to contact Hirotaka Sano to set up meeting with client.